The Bently Nevada 167699-02 is a display module designed for the Bently Nevada 1900/65A machinery protection system. It serves as an operator interface for monitoring and displaying vibration data from rotating machinery. This module is a crucial component of the Bently Nevada 1900/65A system, providing users with a graphical interface to view vibration trends, alarms, and other data. It enables operators to control the machinery protection system and perform diagnostic tasks. The Bently Nevada 167699-02 features a compact size, buffered outputs, and optional display/keypad functionality. It supports various communication protocols, making it highly versatile for integration with other control systems. Its robust design ensures reliable operation in harsh industrial environments. The Bently Nevada 167699-02 is widely used in industries such as oil and gas, power generation, manufacturing, and water treatment for equipment health monitoring and preventive maintenance. It is an ideal solution for continuous monitoring and protection of critical equipment.

Technical Specifications

Parameter Value
Product Model Bently Nevada 167699-02
Manufacturer Bently Nevada
Product Type Display Module
Input Voltage 24V DC
Operating Temperature -40°C to 70°C
Communication Protocols Ethernet, Modbus, PROFIBUS
Digital Inputs 16 channels
Analog Inputs 8 channels
Dimensions 196.9 mm x 149.4 mm x 32.8 mm
Weight 0.40 kg
Mounting Type DIN rail
Protection Rating IP20

Key Features and Benefits

The Bently Nevada 167699-02 offers several standout features that enhance its functionality and reliability in industrial settings. Its graphical user interface allows operators to view vibration trends, alarms, and other critical data, enabling real-time monitoring of equipment health. The module supports multiple communication protocols, including Ethernet and Modbus, ensuring seamless integration with various industrial control systems. Its compact size makes it suitable for space-constrained installations, while the buffered outputs provide protection against short circuits and electromagnetic interference. The optional display/keypad functionality allows users to view channel information and make minor configuration adjustments, enabling the Bently Nevada 167699-02 to function as a standalone unit. The display can be located up to 75 meters away from the monitor module, offering flexibility in system design. The module’s robust build quality ensures reliable operation in harsh industrial environments, minimizing downtime and reducing maintenance costs. Its high-precision sensors and advanced data analysis capabilities provide accurate and timely diagnostic information, helping operators detect potential issues early and maintain optimal equipment performance.

Application Scenarios

The Bently Nevada 167699-02 is widely used in various industrial applications. In power plants, it monitors and protects critical equipment such as generators and turbines, ensuring stable and efficient power generation. In oil and gas refineries, it provides real-time monitoring of pumps and compressors, helping to prevent equipment failures and maintain production continuity. In manufacturing plants, it is used to monitor the condition of motors, fans, and other rotating machinery, enabling predictive maintenance and reducing downtime. In water treatment facilities, it monitors pumps and blowers, ensuring efficient water treatment processes. The Bently Nevada 167699-02 is also applied in industries such as pulp and paper, mining, and cement, providing continuous monitoring and protection for a wide range of equipment assets.

Related Models

172323-01 – A variant of the Bently Nevada 167699-02 with enhanced communication capabilities, supporting optional display/keypad functionality for greater flexibility in system configuration. 1900/65A – The main module of the Bently Nevada 1900/65A machinery protection system, designed for continuous monitoring and protection of rotating machinery. 168547-0010-02-01 – A 3-meter TEF cable assembled for connecting the monitor module to other system components. 173400-01 – A 30-meter PVC cable assembled for extended-distance connections between system components. 1900/65 Modbus Gateway Users Guide – A user guide providing detailed instructions on configuring and using the Modbus gateway functionality of the 1900/65A system.

Installation and Maintenance

Before installing the Bently Nevada 167699-02, ensure the installation environment meets the following requirements: The ambient temperature should be within the range of -40°C to 70°C, with humidity not exceeding 95% non-condensing. The installation location should be free from conductive contaminants and corrosive gases. The module should be mounted on a stable DIN rail to ensure secure installation. Adequate space should be provided around the module for heat dissipation and maintenance access. For maintenance of the Bently Nevada 167699-02, regular inspections of power connections and communication interfaces are recommended to ensure secure and reliable operation. Periodically check the module’s status indicators to identify potential issues early. It is advisable to perform comprehensive maintenance and calibration every six months to one year, depending on the operating environment and usage frequency. If the module shows signs of aging or performance degradation, consider replacing it promptly to ensure system reliability.

Product Warranty

The Bently Nevada 167699-02 comes with a comprehensive warranty that reflects Bently Nevada’s confidence in the product’s quality and performance. The warranty covers defects in materials and workmanship, ensuring reliable operation for the specified period. Bently Nevada offers global support services, with a network of technical experts and service centers available to assist customers with any issues that may arise. The company is committed to customer satisfaction, providing timely responses and effective solutions to minimize downtime and ensure smooth operation of automation systems. This commitment extends beyond the warranty period, with ongoing support and maintenance options available to extend the service life of the Bently Nevada 167699-02 and maximize its value in industrial applications.

BENTLY 126632-01 Cable/terminal/Matching
BENTLY 128031-01 Control board terminal
BENTLY 128085-01 Dual output module
BENTLY 128275-01 External control board terminates
BENTLY 128275-01-E Digital input terminal panel
BENTLY 131151-01 board card
BENTLY 132417-01 DO card
BENTLY 132419-01 Data collector
BENTLY 133300-01 Analog input module
BENTLY 133396-01 DCS/ Distributed control system
BENTLY 135137-01 Programmable logic controller